GREENOX GNX-M10








GREENOX GNX-M10

PLACES OF USE
It is ideal for disinfection and sterilization of kitchen utensils (such as plates, glasses, spoons, forks and knives) in common areas (home, workplace, hotel, school, gym, playground, cinema halls, cafe, restaurant, shopping mall…). It eliminates harmful bacteria, viruses, mold and fungi by 99.9% quickly and without leaving any residue. It does not leave any chemicals and does not require consumables. After the cleaning process is completed, singlet oxygen is halved in a short time and returns to oxygen form.
OPERATION OF THE DEVICE
- The device is positioned in a suitable place.
- The electrical power cable is connected to the device.
- The cable (220 VAC) is plugged into the socket.
- The POWER button on the back of the device is turned on.
- The appropriate and desired mode is selected from the LCD screen and the device starts working.
- When you want to turn it off, the POWER button on the back of the device is turned off.
- The cable (220 VAC) is removed from the socket.
DEVICE SAFETY RULES
- Liquid should not be allowed into the device.
- The environment where the device operates should be dry and moisture-free.
- The cover of the device should not be opened. The plug should not be removed directly while the device is operating, and the power button of the device should be turned off first.
- No object should be placed on the device.
THINGS TO BE CONSIDERED WHEN USING THE DEVICE
- The device must be supplied with 220-240 VAC and 50 Hz electricity.
- The environment in which the device will operate must be at room temperature.
- The device must not be operated under direct sunlight.
- The device must not be operated in dusty or airless places.
THINGS TO BE CONSIDERED DURING HANDLING AND TRANSPORTATION
- The device must be in a vertical position during transportation.
- In order to protect the device to be transported against moisture, attention must be paid to its packaging and a moisture trap must be placed inside.
- The device must be protected against physical damage and falling during transportation.
THINGS TO BE CONSIDERED DURING CLEANING AND MAINTENANCE
- The maintenance of the device should only be done on the dates determined by the authorized company.
- The user should not open the inside of the device.
- After the power plug of the device is removed from the socket, the outer parts should be wiped with a slightly damp cloth and then dried.
- Liquid should not be allowed into the device.
- The device should not be cleaned with any chemicals.
DEVICE DIMENSIONS AND TECHNICAL SPECIFICATIONS
| Brand | GREENOX | ||||
| Model | GNX-M10 | GNX-M15 | GNX-M20 | GNX-M25 | GNX-M50 |
| Capacity | 10 gr/hour | 15 gr/hour | 20 gr/hour | 25 gr/hour | 50 gr/shourat |
| Power | 90 W | 100 W | 110 W | 120 W | 150 W |
| Weight | 15 Kg | 15 Kg | 15 Kg | 15 Kg | 15 Kg |
| Operating Voltage | 220-240 VAC 50 Hz | 220-240 VAC 50 Hz | 220-240 VAC 50 Hz | 220-240 VAC 50 Hz | 220-240 VAC 50 Hz |
| Dimensions | 400mm/400mm/500mm | 400mm/400mm/500mm | 400mm/400mm/500mm | 400mm/400mm/500mm | 400mm/400mm/500mm |
| Usage Mode | Manual-Automatic-Full | Manual-Automatic-Full | Manual-Automatic-Full | Manual-Automatic-Full | Manual-Automatic-Full |
| *May require the use of an external oxygen concentrator. | |||||