GREENOX GNX-A100

PLACES OF USE

It is ideal for disinfection, sterilization and deodorization of all vehicles. It eliminates harmful bacteria, viruses, mold and fungi by 99.9% quickly and without leaving any residue. It does not leave any chemicals and does not require consumables. After the cleaning process is completed, singlet oxygen is halved in a short time and returns to oxygen form.

OPERATION OF THE DEVICE

  • The device is positioned in a suitable place.
  • The electrical power cable is connected to the device.
  • The cable (220 VAC) is plugged into the socket.
  • The POWER button on the back of the device is turned on.
  • The appropriate and desired mode is selected from the LCD screen and the device starts working.
  • When you want to turn it off, the POWER button on the back of the device is turned off.
  • The cable (220 VAC) is removed from the socket.

DEVICE SAFETY RULES

  • Liquid should not be allowed into the device.
  • The environment where the device operates should be dry and free of moisture.
  • The cover of the device should not be opened.
  • The plug should not be removed directly while the device is operating, and the power button of the device should first be turned off.
  • No object should be placed on the device.

THINGS TO BE CONSIDERED WHEN USING THE DEVICE

  • The device must be supplied with 220-240 VAC and 50 Hz electricity.
  • The environment in which the device will operate must be at room temperature.
  • The device must not be operated under direct sunlight.
  • The device must not be operated in dusty or airless places.

THINGS TO BE CONSIDERED DURING HANDLING AND TRANSPORTATION

  • The device must be in a vertical position during transportation.
  • In order to protect the device to be transported against moisture, attention must be paid to its packaging and a moisture trap must be placed inside.
  • The device must be protected against physical damage and falling during transportation.

THINGS TO BE CONSIDERED DURING CLEANING AND MAINTENANCE

  • The maintenance of the device should only be done on the dates determined by the authorized company.
  • The user should not open the inside of the device.
  • After the power plug of the device is removed from the socket, the outer parts should be wiped with a slightly damp cloth and then dried.
  • Liquid should not be allowed into the device.
  • The device should not be cleaned with any chemicals.

DEVICE DIMENSIONS AND TECHNICAL SPECIFICATIONS

BrandGREENOX
ModelGNX-A100GNX-A200
Capacity100 gr/hour200 gr/hour
Power250 W300 W
Weight15 Kg15 Kg
Operating Voltage220-240 VAC 50 Hz220-240 VAC 50 Hz
Dimensions500mm/500mm/600mm500mm/500mm/600mm
Usage ModeManual-Automatic-FullManual-Automatic-Fulll